Desa DVF34 Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Kamna Desa DVF34. Desa DVF34 User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 36
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
DIRECT-VENT FIREPLACE
OWNER’S OPERATION AND INSTALLATION MANUAL
NATURAL GAS MODEL DVF34
PROPANE/LP GAS MODEL DVF34P
Save this manual for future reference.
FOR YOUR SAFETY
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch
Do not use any phone in your building.
Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.
If you cannot reach your gas supplier, call
the fire department.
WARNING: Improper installation,
adjustment, alteration, service, or
maintenance can cause injury or
property damage. Refer to this
manual for correct installation and
operational procedures. For assis-
tance or additional information con-
sult a qualified installer, service
agency, or the gas supplier.
This appliance may be installed in an aftermarket* manufactured (mobile) home,
where not prohibited by state or local codes.
WARNING: If the information in this manual is
not followed exactly, a fire or explosion may
result causing property damage, personal in-
jury, or loss of life.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
— Installation and service must
be performed by a qualified in-
staller, service agency, or the gas
supplier.
This appliance is only for use
with the type of gas indicated on
the rating plate. This appliance is
not convertible for use with other
gases, unless a certified kit is
used.
*Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer.
Zobrazit stránku 0
1 2 3 4 5 6 ... 35 36

Shrnutí obsahu

Strany 1 - DIRECT-VENT FIREPLACE

DIRECT-VENT FIREPLACEOWNER’S OPERATION AND INSTALLATION MANUALNATURAL GAS MODEL DVF34PROPANE/LP GAS MODEL DVF34PSave this manual for future reference.

Strany 2

10106424DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP)DVF34, DVF34PVENTINGINSTALLATIONContinuedUPUPHorizontal VentingVertical (V) Horizontal (H)37" m

Strany 3

11106424OWNER’S MANUALVENTINGINSTALLATIONContinuedUPVenting with Two 90° ElbowsVertical (V) Horizontal (H1) Horizontal (H1) +Horizontal (H2)5' mi

Strany 4 - PREPARATION

12106424DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP)DVF34, DVF34P4. Connect a section of pipe and extendup through the hole.Note: If an offset is needed

Strany 5 - GENERAL VENTING

13106424OWNER’S MANUALVENTINGINSTALLATIONContinuedContinuedFigure 22 - Cathedral Ceiling SupportBox InstallationNon-hardening Mastic under alledges of

Strany 6

14106424DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP)DVF34, DVF34PVertical VentingV = 40' max.Figure 27 - Vertical Rigid VentingConfiguration With N

Strany 7

15106424OWNER’S MANUALVENTINGINSTALLATIONContinuedHIGH ALTITUDEINSTALLATIONYour FMI direct-vent fireplace has beenAGA tested and approved for elevatio

Strany 8

16106424DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP)DVF34, DVF34PINSTALLING OPTIONALBLOWER ACCESSORYIMPORTANT: For clarity, gas valve assem-bly and grat

Strany 9

17106424OWNER’S MANUALFIREPLACEINSTALLATIONContinued WARNING: Never touch theblower wheel while in operation.10. Peel off the backing paper and stick

Strany 10 - INSTALLATION

18106424DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP)DVF34, DVF34PFigure 34 - Gas Connection* The CSA design-certified equipment shutoff valve may be sup

Strany 11

19106424OWNER’S MANUALPressure Testing Gas SupplyPiping SystemTest Pressures In Excess Of 1/2 PSIG(3.5 kPa)1.Disconnect appliance with its appliancema

Strany 12

2106424DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP)DVF34, DVF34PSAFETYINFORMATION1. This appliance is only for use with thetype of gas indicated on the

Strany 13

20106424DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP)DVF34, DVF34PFIREPLACEINSTALLATIONContinuedTest Pressures Equal To or Less Than1/2 PSIG (3.5 kPa)1.

Strany 14

21106424OWNER’S MANUALFIREPLACEINSTALLATIONContinuedFigure 39 - Attaching Alkaline Battery toReceiver9-Volt AlkalineBatteryReceiverTerminalWiresBatter

Strany 15 - FMI Rigid Venting

22106424DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP)DVF34, DVF34PINSTALLING OPTIONALBRICK LINER D8037A WARNING: If fireplace hasbeen running, turn off a

Strany 16 - FIREPLACE

23106424OWNER’S MANUAL WARNING: The glass doormust be securely in place beforerunning this fireplace. Do not runthis fireplace if glass is missingor b

Strany 17

24106424DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP)DVF34, DVF34PMANUAL LIGHTINGPROCEDUREOPERATINGFIREPLACE WARNING: If you do not fol-low these instruc

Strany 18 - IMPORTANT:

25106424OWNER’S MANUALOFFPILOTONLOIHONOFFREMOTEONOFFOPERATINGFIREPLACEContinuedOPERATINGOPTIONAL BLOWERACCESSORYLocate the blower controls by openingt

Strany 19 - Piping System

26106424DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP)DVF34, DVF34PPILOT AND BURNERS• Remove ember material before cleaningburners and replace when cleani

Strany 20 - Connections

27106424OWNER’S MANUALTROUBLESHOOTING WARNING: Turn off heaterand let cool before servicing. Onlya qualified service person shouldservice and repair

Strany 21

28106424DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP)DVF34, DVF34POBSERVED PROBLEMBurner does not light after pilot is litDelayed ignition burnerBurner b

Strany 22 - Brass Strips

29106424OWNER’S MANUALTROUBLESHOOTINGContinued WARNING: If you smell gas• Shut off gas supply.• Do not try to light any appliance.• Do not touch any e

Strany 23

3106424OWNER’S MANUALPRODUCTIDENTIFICATIONInstall and use fireplace with care. Followall local codes. In the absence to local codes,use the current Na

Strany 24

30106424DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP)DVF34, DVF34PSERVICE HINTSWhen Gas Pressure Is Too Low• pilot will not stay lit• burners will have d

Strany 25 - INSPECTING

31106424OWNER’S MANUALSPECIFICATIONSDVF34 DVF34PBtu 15,000/21,000 Btu/h 16,000/20,000 Btu/hGas Type Natural Propane/LPIgnition Piezo PiezoManifold Pre

Strany 26 - Replacement Parts

32106424DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP)DVF34, DVF34P471234663555511 (Included inHardware Pack)778109121314151617181920322122232425262728282

Strany 27 - TROUBLESHOOTING

33106424OWNER’S MANUALPARTS LISTDIRECT-VENT FIREPLACEDVF34DVF34PThis list contains replaceable parts used in your fireplace. When ordering parts, foll

Strany 28

34106424DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP)DVF34, DVF34PMANUAL BLOWER KITGA3700Manual-variable control blower accessory forthe DVF Series firep

Strany 29

35106424OWNER’S MANUALNOTES___________________________________________________________________________________________________________________________

Strany 30 - When Gas Quality Is Bad

LIMITED WARRANTYDIRECT-VENT FIREPLACEDESA International warrants this product to be free from defects in materials and components for two (2) years fr

Strany 31 - SPECIFICATIONS

4106424DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP)DVF34, DVF34PFireplace size D x FW x RW34" 18 1/2" 34 3/8" 14"PRE-INSTALLATIONPRE

Strany 32

5106424OWNER’S MANUAL29"13"12 5/8"34 3/8"35 1/16"58"9 1/4"41"Nailing TabsPRE-INSTALLATIONPREPARATIONContinuedF

Strany 33

6106424DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP)DVF34, DVF34PFigure 8 - Minimum Clearances for Vent TerminationsGENERAL VENTING ContinuedFixedClosedO

Strany 34 - ACCESSORIES

7106424OWNER’S MANUAL WARNING: Read all instruc-tions completely and thoroughlybefore attempting installation. Fail-ure to do so could result in serio

Strany 35

8106424DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP)DVF34, DVF34PINSTALLATION FORHORIZONTAL TERMINATION1. Determine the route your horizontalventing will

Strany 36 - NOT A UPC

9106424OWNER’S MANUALVENTINGINSTALLATIONContinued(FramingDetail)10"(254mm)10"(254mm)7 1/2"(190mm)Vent OpeningCombustible WallVent Openi

Příbuzné modely DVF34P

Komentáře k této Příručce

Žádné komentáře