OWNER’S OPERATION AND INSTALLATION MANUAL
INFRARED VENT-FREE NATURAL GAS HEATER
Model: CGN10R
Save this manual for future reference.
®
WARNING: If the information in this manual is not followed exactly, a fire or
explosion may result causing property damage, personal injury, or loss of life.
Do not store or use gasoline or other flammable vapors and liquids in the
vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Immediately call your gas supplier from a neighbor’s phone. Follow the gas
supplier’s instructions.
If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service
agency, or the gas supplier.
This appliance may be installed in an aftermarket* manufactured (mobile) home,
where not prohibited by state or local codes.
* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer
This appliance is only for use with the type of gas indicated on the rating plate.
This appliance is not convertible for use with other gases.
Zobrazit stránku 0
1 2 3 4 5 6 ... 27 28

Shrnutí obsahu

Strany 1 - Model: CGN10R

OWNER’S OPERATION AND INSTALLATION MANUALINFRARED VENT-FREE NATURAL GAS HEATERModel: CGN10RSave this manual for future reference.®WARNING: If the info

Strany 2 - CONTENTS

101018672. Mark two mounting screw locations on wall (see Figure 5).INSTALLING HEATER TO WALLMarking Screw Locations1. Determine where you will locate

Strany 3

11101867Installing Two Mounting ScrewsNote: Wall anchors and mounting screws are in hardware package. The hardwarepackage is provided with heater.Atta

Strany 4

12101867Placing Heater On Mounting Screws1. Locate two keyhole slots on back panel of heater (see Figure 9).2. Place large openings of slots over scre

Strany 5 - VENTILATION

13101867 WARNING ICON G 001 WARNINGNever connect heater to private (non-utility) gas wells. This gas iscommonly known as well-head gas. NOTICEA quali

Strany 6

14101867ManualShutoff Valve *IMPORTANT: Hold pressure regulator with wrench when connecting it to gas pipingand/or fittings.Figure 12 - Gas Connectio

Strany 7

151018674. Check all joints of gas supply piping system. Apply mixture of liquid soap andwater to gas joints. Bubbles forming show a leak.5. Correct a

Strany 8

16101867OPERATINGHEATERFOR YOUR SAFETY READ BEFORE LIGHTINGA. This appliance has a pilot which must be lighted by hand. When lightingthe pilot, follow

Strany 9

171018674. Wait five (5) minutes to clear out any gas. Then smell for gas, includingnear the floor. If you smell gas, STOP! Follow “B” in the safety i

Strany 10 - INSTALLING

18101867TO SELECT HEATING LEVEL1. Slightly press in control knob and turn counterclockwise C-clockwise to theLOW or HIGH positions.IMPORTANT: Release

Strany 11

19101867GRH/OV 009GOOD PILOTGRH/OV 008BAD PILOT/LPShutting Off Heater1. Turn control knob clockwise Clockwise to the OFF position.Shutting Off Burner

Strany 12

2101867CONTENTSSECTION PAGESafety Information ... 2Product Identification ...

Strany 13 - WARNING ICON G 001

20101867BURNER FLAME PATTERNFigure 20 shows a correct burner flame pattern. Figure 21 shows an incorrectburner flame pattern.Figure 20 - Correct Burne

Strany 14

21101867CLEANINGANDMAINTENANCEWARNING ICON G 001 WARNINGTurn off heater and let cool before cleaning.WARNING ICON G 001 CAUTIONYou must keep control a

Strany 15 - POSITION

22101867REMEDY1. Turn on gas supply oropen manual shutoffvalve2. Turn control knob toPILOT position3. Press in control knobwhile in PILOTposition4. Co

Strany 16 - LIGHTING INSTRUCTIONS

23101867OBSERVEDPROBLEMBurner(s) does notlight after ODS/pilotis litDelayed ignition ofburner(s)Burner backfiringduring combustionBurner plaque(s) doe

Strany 17 - OPERATING

24101867TROUBLE-SHOOTINGContinuedTECHNICALSERVICEYou may have further questions about installation, operation, or troubleshooting.If so, contact DESA

Strany 18 - TO SELECT HEATING LEVEL

25101867SPECIFICATIONSBtu (Variable) 5,500/10,000Type Gas Natural OnlyIgnition PiezoPressure Regulator Setting 3" W.C.Inlet Gas Pressure (inches

Strany 19 - INSPECTING

26101867PARTSCENTRALSThese Parts Centrals are privately owned businesses. They have agreed to supportour customer’s needs by providing original replac

Strany 20

27101867KEY PARTNO. NUMBER DESCRIPTION QTY.16 098276-01 1/8 Pipe Plug 117 099468-07 Cabinet Assembly 118 099415-01 Gas Regulator 119 098303-02 Screw,

Strany 21 - SHOOTING

LIMITED WARRANTYCOMFORT GLOW VENT-FREE RESIDENTIAL GAS HEATERSDESA International warrants this product to be free from defects in materials and compon

Strany 22

3101867SAFETYINFORMATIONContinued WARNING ICON G 001 WARNINGS ContinuedWARNING: Any change to this heater or its controls can be dangerous.1. This

Strany 23

4101867PRODUCTIDENTIFICATIONLOCAL CODESInstall and use heater with care. Follow all local codes. In the absence of localcodes, use the latest edition

Strany 24 - TECHNICAL

5101867FRESH AIRFORCOMBUSTIONANDVENTILATIONWARNING ICON G 001 WARNINGThis heater shall not be installed in a confined space unlessprovisions are provi

Strany 25 - REPLACEMENT

6101867FRESH AIRFORCOMBUSTIONANDVENTILATIONContinuedDETERMINING FRESH-AIR FLOW FOR HEATER LOCATIONDetermining if You Have a Confined or Unconfined Spa

Strany 26 - PUBLICATIONS

7101867FRESH AIRFORCOMBUSTIONANDVENTILATIONContinuedOr Remove Door into Adjoining Room, Option 3Ventilation Grills Into Adjoining Room,Option 212"

Strany 27 - PARTS LIST

8101867FRESH AIRFORCOMBUSTIONANDVENTILATIONContinuedFigure 3 - Ventilation Air from OutdoorsOutletAirVentilatedAttic OutletAirInletAirInlet AirVentila

Strany 28 - WARRANTY INFORMATION

9101867INSTALLINGTO WALLContinuedNOTICEA qualified service person must install heater. Follow all local codes.CHECK GAS TYPEUse only natural gas. If y